In a science classroom, a fume hood has two jobs. It has to protect the instructor and students from fumes, and it has to let a room full of students see what is happening inside. A standard benchtop hood against a wall does the first job well but not the second. That is where a teaching, or demonstration, fume hood comes in.
What is a teaching fume hood?
A teaching fume hood is usually a double-entry hood: it has a glass sash on the front and the back, so it can be used and viewed from both sides. It sits on an island rather than against a wall. The instructor demonstrates from the prep side while students watch, or work, from the other.
The DemoPro PassThru is built for this. It has vertical rising glass sashes on both sides, an FRP liner, LED lighting and an airflow alarm, and it is UL listed and ASHRAE 110 tested.
Why not just use a standard hood?
- Visibility: with a wall-mounted hood, only a few students can see in at once. A double-entry hood on an island can be seen from the whole room.
- Classroom layout: an island hood can sit at the front or center of the room, as part of the demonstration area.
- Teaching flexibility: students can work at the hood from their side while the instructor supervises from the other.
What to look for
Size
Teaching hoods are usually compact. The DemoPro comes in 48" and 60" widths, with a 40" or 52" wide opening. A 48" hood suits a single demonstration area; a 60" hood gives room for more equipment or two students working at once.
Sash and visibility
Look for clear glass sashes on both sides and good interior lighting. Sash stops, which on the DemoPro are at 18", keep the opening at the working height the exhaust is designed for.
Plumbing
Decide whether you need cold water, gas or both, and on which side. The DemoPro offers cold water, gas, or cold water and gas, on the prep side only or on both sides. Cold water needs a worksurface with a cup sink.
Safety features
- An airflow monitor that alarms when airflow drops. The DemoPro includes an AFA 500.
- GFI receptacles for hot plates and stirrers.
- A chemical-resistant liner. The DemoPro uses fiberglass reinforced polyester (FRP).
- UL listing and ASHRAE 110 testing.
Service access
Removable side panels and interior access panels make installation and maintenance easier, which matters in schools where facilities staff handle many buildings.
Planning the classroom installation
- Island support: the DemoPro is 32.94" deep from front post to rear and sits on a 30" deep worksurface over island base cabinets. Fume hood base cabinets include island versions.
- Exhaust: plan ductwork and a blower sized to the hood. The 48" DemoPro needs about 500 CFM at an 18" sash and 100 fpm.
- Sightlines: place the hood where students can gather on the viewing side without blocking aisles or exits.
- Drafts: keep the hood away from doors and supply air diffusers.
- Storage: put chemical storage near the prep side, not the student side. See acid vs. flammable storage cabinets.
Our fume hood installation checklist covers the rest.
Classroom safety habits
- Keep sashes at or below the sash stop during demonstrations.
- Work at least 6" inside the sash.
- Teach students what the airflow alarm means and what to do when it sounds.
- Don't store chemicals inside the hood.
- Have the hood's face velocity checked regularly and keep the test label current.
Learn more
See the DemoPro PassThru, download its cut sheet and installation manual from Resources, or call 616-407-0252 to plan your classroom.