How to Choose a Benchtop Fume Hood: A Buyer's Guide

Two benchtop fume hoods on steel base cabinets with acid and flammable storage and exhaust ducts above

A chemical fume hood is the most important piece of safety equipment in most labs, and it is also one of the most expensive to get wrong. A hood that is too small crowds your work, one that is too large wastes conditioned air, and one that doesn't match your building's exhaust won't protect anyone. This guide covers the decisions that matter when you buy a benchtop fume hood.

AirGuard Pro benchtop fume hood on steel base cabinets with an epoxy worksurface

1. Confirm what you'll use it for

A standard chemical fume hood is built for general chemistry: acids, bases, solvents and the vapors they give off. Some work needs a specialized hood instead:

  • Perchloric acid needs a dedicated perchloric hood with a washdown system, because perchlorate residue in ductwork can become explosive.
  • Radioisotopes need a hood designed and approved for radioactive materials.
  • Biological work usually calls for a biological safety cabinet, not a fume hood. A fume hood protects the user but not the sample.

Talk with your safety officer about the chemicals and quantities involved before you choose. Our AirGuard Pro and DemoPro hoods are general-purpose chemical fume hoods and are not for perchloric acid or radioactive materials.

2. Pick the right width

Benchtop hoods are sold by nominal width. Choose based on how many people work at the hood at once and the largest setup you'll put inside it:

  • 48": one person, small setups and teaching labs with limited space.
  • 60" and 72": the most common choices for research and QC labs. Room for one person with larger equipment, or two people working side by side.
  • 96": large apparatus, distillation setups or several users.

AirGuard Pro fume hood widths drawn to scale: 48, 60, 72 and 96 inch, with opening widths and CFM at an 18 inch sash

Remember that a wider hood exhausts more air. Every cubic foot pulled out of the room has to be replaced with heated or cooled makeup air, so buy the size you need rather than the biggest that fits.

3. Understand airflow: bypass hoods and face velocity

Face velocity is the speed of air moving into the hood opening, in feet per minute (fpm). Many labs design around 100 fpm. In a bypass hood, an opening above the sash lets air keep flowing as the sash closes, so the face velocity doesn't spike and the exhaust volume stays steady. The AirGuard Pro is a bypass hood that performs down to 60 fpm, which can reduce the amount of air your building has to exhaust and condition.

The required exhaust, in cubic feet per minute (CFM), depends on the opening size and the face velocity. Our guide to fume hood face velocity and CFM explains the math and lists the numbers for each size.

4. Decide on plumbing and electrical

Order the services you need built in. Adding them later means cutting into the hood and running new lines.

  • Cold water for rinsing and cooling, which needs a worksurface with a cup sink and a drain connection.
  • Gas for burners.
  • Electrical receptacles for stirrers, hot plates and other equipment. GFI receptacles mounted outside the work area are standard.

The AirGuard Pro comes with no plumbing, cold water, gas, or cold water and gas, factory pre-plumbed, along with LED lighting and two GFI receptacles.

5. Look at construction and the liner

The liner is the surface that faces fumes and spills. Fiberglass reinforced polyester (FRP) is a widely used liner with broad chemical and corrosion resistance. Also look at the superstructure (steel gauge and finish), the sash (vertical rising, with a sash stop at the working height), the baffles that distribute airflow, and whether side panels are removable for service access.

6. Check certifications and monitoring

  • UL listing covers the hood's electrical safety.
  • ASHRAE 110 is the standard test of how well a hood contains fumes, using tracer gas, airflow visualization and face velocity measurements.
  • An airflow monitor warns users when airflow drops. Every LabSpace hood includes an AFA 500 airflow alarm.

Both of our hoods are UL listed and ASHRAE 110 tested. See Certifications & Standards.

7. Plan what goes under and behind it

A benchtop hood is only one part of the installation. You also need:

Our fume hood installation checklist walks through each item.

8. Choose a good location

Place the hood away from doors, busy walkways and supply air diffusers. Cross drafts from people walking by or air blowing across the opening can pull fumes out of the hood. Leave room for the sash to open fully and for service access to the side panels.

Quick checklist

Decision What to confirm
Application General chemistry, not perchloric or radioactive work
Width 48", 60", 72" or 96" based on users and setups
Airflow Face velocity and CFM your building can support
Services Water, gas, electrical
Certifications UL listed, ASHRAE 110 tested, airflow monitor
Support Worksurface, base cabinets, storage
Building Ductwork, blower, makeup air, location

Find the right hood

Compare sizes, airflow and options in our fume hood collection, download cut sheets and manuals from Resources, or call 616-407-0252 to talk through your lab.